Water purifier diagnostics
Your RO output TDS is very low — when that matters
Below about 50 ppm you are drinking near-demineralised water: it tastes flat, and you have discarded the calcium and magnesium your supply was giving you for free. It is a taste and nutrition question rather than an acute safety one, and it is usually correctable without new hardware.
Does this match your symptoms?
- Output TDS consistently under 30-40 ppm
- Water tastes flat, empty or metallic
- Food and tea taste different since installing the purifier
- Your input supply was already low-TDS
Work through the causes in this order
Ordered by how often each turns out to be the real cause — not by what it costs to fix. 1 of these costs nothing to resolve.
- Most commonTechnician jobUp to ₹400
1. TDS controller closed, or not fitted
How to confirm it
Check whether your model has a TDS controller or mineral blend valve. If it does and output is under 40 ppm, it is closed or nearly so. If it does not have one at all, the unit will always drive output to the floor and there is nothing to adjust.
The fix
Have the TDS controller opened to bring output into the 50-150 ppm range. It is a valve adjustment and should not cost a part.
- CommonTechnician jobFree to fix
2. RO fitted on supply that never needed it
How to confirm it
Measure the input TDS at the inlet tap. Below 200 ppm, RO was the wrong technology — UV plus UF would have disinfected the water without stripping it, at a fraction of the running cost and with no reject water at all.
The fix
If the unit is new, this is worth raising with whoever sold it. If you are keeping it, open the TDS controller as far as it goes. When it comes time to replace, do not buy RO again unless your supply has changed.
Part: None — this is a specification error rather than a fault
- CommonYou can fix this₹400 – ₹1,200
3. Exhausted mineraliser cartridge
How to confirm it
Applies to units with a mineral or alkaline stage. These cartridges deplete, typically within 6-12 months, after which output TDS falls back to raw membrane output and the water goes flat again.
The fix
Replace the mineraliser cartridge on the maker's schedule. Note that this is only worth doing if you genuinely needed RO in the first place.
Part: Mineral / alkaline cartridge
When to stop and call a technician
- Your unit has no TDS controller and you want output raised — this may need a blend valve retrofitted
- You want to establish whether you needed RO at all, which starts with a proper input measurement
When replacement beats repair
Your input TDS is consistently below 200 ppm — at which point RO costs more to buy, more to run, wastes water and removes minerals you wanted.