Skip to content
capacity2000 LPH₹12 lakh - ₹22 lakh

2000 LPH Industrial RO Plant — Price, Specs & Suitability

2000 LPH industrial RO plant: indicative price ₹12 lakh - ₹22 lakh, technical specification, power requirement and suitability. Request a quotation with your water report.

2000 LPH — system illustration
  • Pan-India installation & service
  • AMC support available
  • Free site water-quality audit
  • Custom-engineered to your TDS
TCO calculator →

Request a technical quote

Our team will size a system against your requirement and send a specification-backed proposal.

+91

We use your details only to respond to this enquiry. See our privacy policy.

Capacity range
2000 LPH
Indicative capex
₹12 lakh - ₹22 lakh
Installation lead time
7 – 14 days
Annual AMC
10 – 14% of capex

2,000 LPH plants serve large factories, packaged drinking water operations, textile processing and food manufacturing. PLC with HMI and data logging becomes standard, SS-316 wetted parts are commonly specified, and online conductivity and flow instrumentation is expected rather than optional.

At this scale, reject water volume becomes a compliance consideration in its own right — a plant at 50% recovery discharges 2,000 litres an hour of concentrate, and the disposal or reuse route should be settled before the plant is ordered.

Technical specification

ParameterSpecification
Rated output2000 litres per hour (approx. 16000-20000 L per working day)
ClassIndustrial
Typical applicationLarge factories, packaged drinking water plants, textile and food processing
Indicative capex₹12 lakh - ₹22 lakh
Power10-15 HP, three phase
FootprintApprox. 5 x 2 m plus utilities
ConstructionSS-304 skid; SS-316 wetted parts optional
Pre-treatmentMultigrade sand + activated carbon + antiscalant dosing
ControlPLC / microprocessor with auto flushing and interlocks
Post-treatmentUV disinfection; mineral dosing optional

Figures are indicative planning ranges for budgetary approval, not quotations. Actual cost and achievable output depend on your feed-water analysis, materials of construction, automation level, instrumentation, storage and site conditions.

What this capacity actually delivers

A 2000 LPH plant produces around 2000 litres of treated water for every hour it runs — so roughly 16000 to 20000 litres across a normal working day, depending on run hours and storage.

Two adjustments matter in practice. Rated output assumes design feed conditions; as feed TDS rises and membranes age, actual output falls, typically by 10-20% over a membrane's life. And if your demand is concentrated into a short peak, storage rather than extra plant capacity is almost always the cheaper answer.

  • PLC + HMI with data logging
  • SS-316 wetted parts available
  • Multi-stage array with high recovery configuration
  • Online conductivity and flow instrumentation
  • Optional DM / mixed-bed polishing

Is this the right size for you?

This capacity is typically specified for: large factories, packaged drinking water plants, textile and food processing.

If your requirement sits near the boundary between two capacities, size up. Running a plant at 95% of rated capacity continuously shortens membrane and pump life, and leaves no headroom for growth or for the output decline that comes with membrane ageing.

Multi-stage purification architecture

Commercial and industrial systems are engineered as a treatment train, not a single appliance. Each module protects the one after it, and skipping a stage to save capex is the most common reason plants fail early.

  • Pre-treatment module — multigrade sand filter removes suspended solids and turbidity; activated carbon filter strips chlorine and organics that would oxidise the RO membrane.
  • Softening or antiscalant dosing — protects membranes from calcium and magnesium scaling. On hard feed water this is not optional.
  • High-pressure RO module — heavy-duty booster pump drives feed water through industrial spiral-wound membranes at 12-18 bar.
  • Post-treatment disinfection — UV disinfection and/or ozonation, with mineral dosing where potable taste matters.
  • Microprocessor / PLC control — auto start-stop on tank level, dry-run protection, low and high pressure cut-offs, and timed membrane flushing to extend membrane life.

Tip

Ask any vendor to show you the pre-treatment specification, not just the RO capacity. An undersized pre-treatment train is the single most common cause of premature membrane failure and unplanned downtime.

Total cost of ownership, not just capex

Capital cost is usually 30-40% of what a commercial water system costs you over five years. The rest is power, membrane and cartridge replacement, reject water, and labour. Two plants with identical price tags can differ by 60% in five-year TCO.

  • Power — energy-efficient pumps and correctly sized motors are the largest controllable operating cost on plants above 500 LPH.
  • Recovery ratio — a plant recovering 70% instead of 45% cuts both your feed water bill and your reject disposal volume substantially.
  • Membrane life — driven almost entirely by pre-treatment quality and flushing discipline, not by membrane brand.
  • Consumables — cartridge filters, antiscalant and salt for softener regeneration, budgeted monthly rather than as surprises.
  • AMC and downtime — for a production facility, unplanned downtime usually dwarfs every other line item.

Installation, commissioning and service response

Commercial buyers are buying uptime, so the commercial terms matter as much as the equipment specification. Insist on these being written into the purchase order rather than discussed verbally.

  • Site survey and feed-water analysis before the final quotation — never accept a specification produced without a water report.
  • Defined commissioning scope: civil and electrical prerequisites, who supplies what, and a documented performance test at handover.
  • Written service response times, with escalation, and clarity on whether spares are held locally.
  • Operator training and a laminated SOP left on site, so routine flushing and cartridge changes do not depend on one person.
  • Warranty terms stated separately for membranes, pumps, vessels and instrumentation, because they differ.

What a quotation includes

  • Feed-water analysis and confirmation of achievable output at your TDS
  • 2000 LPH skid-mounted RO plant with pre-treatment train
  • Storage tank sizing and interconnection
  • Installation, commissioning and performance test
  • Operator training and AMC proposal

Why specify with us

Low total cost of ownership

High-rejection membranes, correctly sized pre-treatment and efficient pumps reduce power draw, consumable spend and reject volume. We quote five-year operating cost alongside capex, because that is the number that actually matters.

Heavy-duty SS-304 / SS-316 build

Corrosion-resistant stainless chassis and wetted parts engineered for continuous 24/7 duty, with SS-316 specified where chlorides or process chemistry demand it.

Rapid on-site servicing & AMC

Pan-India installation and service, with written response times and escalation in the AMC rather than verbal assurances — because plant downtime, not the repair, is your real cost.

Custom TDS tuning

Systems engineered against your actual water analysis — brackish groundwater, municipal supply or heavy borewell input, including high-TDS configurations for 3,000+ ppm feed.

Treatment architecture

  1. 1

    Pre-treatment module

    Multigrade sand and activated carbon filtration strips suspended solids, turbidity and chlorine that would otherwise oxidise the RO membrane.

  2. 2

    Softening / antiscalant dosing

    Protects membranes from calcium and magnesium scaling. On hard feed water this stage is not optional — it determines membrane life.

  3. 3

    High-pressure RO module

    Heavy-duty booster pumps drive feed water through industrial spiral-wound membranes at 12-18 bar in an array sized for your recovery target.

  4. 4

    Post-treatment disinfection

    UV disinfection and ozonation, with mineral dosing where potable taste and consistency matter.

  5. 5

    Microprocessor / PLC controls

    Auto start-stop on tank level, dry-run protection, high and low pressure cut-offs, and timed membrane flushing — with data logging on industrial plants.

Frequently asked questions

What is the price of a 2000 LPH RO plant in India?
Indicatively ₹12 lakh - ₹22 lakh for a 2000 LPH industrial RO plant. The range reflects materials of construction, the pre-treatment train your feed water requires, automation level, instrumentation and whether storage and distribution are included. Because pre-treatment is specified against your actual water chemistry, a firm price needs a feed-water analysis report.
How many people can a 2000 LPH plant serve?
At 3-4 litres of drinking water per person per day and 8-10 hours of daily operation, a 2000 LPH plant supports roughly 4500-6000 people. Add storage of at least one day's demand so that a fault or a maintenance visit does not interrupt supply.
What power supply does a 2000 LPH plant need?
Typically 10-15 HP, three phase. Confirm available load and phase at your site before ordering, since three-phase supply and adequate sanctioned load are prerequisites. Voltage stabilisation is worth considering where supply is erratic, as pump motors are the most failure-prone component.
What is the typical lead time for commercial installation?
Standard commercial systems from 100 to 500 LPH are typically installed within 48-72 hours of site readiness, since they are skid-built and largely pre-assembled. Custom industrial plants generally need 7-14 days depending on site readiness, civil work, electrical provisioning and whether non-standard materials such as SS-316 wetted parts are specified.
Do you offer Annual Maintenance Contracts (AMC)?
Yes. Commercial installations can be covered by comprehensive AMC packages including scheduled preventive visits, membrane and cartridge replacement, and priority breakdown response. Comprehensive AMC (parts included) typically runs 10-14% of capital cost annually; non-comprehensive (labour and visits only) runs 5-8%. Get the inclusions listed line by line before signing.
Can the system integrate with our existing overhead tanks, coolers or chillers?
Yes. Commercial systems use high-pressure sensors and level-based auto start-stop, which allows plug-and-play integration with external storage tanks, water coolers and chillers. Tell us your existing tank capacity, height and any chiller model at enquiry stage so the pump head and control logic are specified correctly.

Need a quote for 2000 lph today?

Share your water analysis report and output requirement, and our technical team will build a system specification with capex, five-year operating cost and AMC options.

Email our technical team

Related commercial solutions

Free consultation · Pan-India

Not sure what you actually need? Ask us before you spend.

Tell us your city, your water source and your budget. For homes we will recommend the right technology — including telling you when a ₹3,000 purifier is genuinely enough. For offices, societies and factories, our team will size a system against your water report and send a specification-backed quotation.

Or email betterworkindia@gmail.com — attach a water analysis report and we can quote faster.

  • Homes

    Right-sized recommendation for your TDS, not the most expensive unit

  • Offices & societies

    25 LPH to 2,000+ LPH, sized on headcount and feed water

  • Industry

    Pharma, food, textile, boiler feed — engineered to your specification

  • Service & AMC

    Installation, repair and AMC with written response times

Pan-India installation & serviceAMC support availableFree site water-quality auditCustom-engineered to your TDSHow our quotation process works →