What Tonnage AC Do You Need for Your Room Size?

7 min readPublished 14 September 2026Updated

The quick answer by room size

Room sizeLoad (middle floor)Buy (middle floor)Buy (top floor, afternoon sun)
100 sq ft (10 × 10 ft)0.75 ton1 ton1 ton
120 sq ft (10 × 12 ft)0.9 ton1 ton1.5 ton
150 sq ft (10 × 15 ft)1.1 ton1.5 ton1.5 ton
180 sq ft (12 × 15 ft)1.35 ton1.5 ton2 ton
200 sq ft (10 × 20 ft)1.5 ton1.5 ton2 ton
250 sq ft1.9 ton2 tonTwo units
300 sq ft (15 × 20 ft)2.25 tonTwo unitsTwo units

Note

Loads use about 90 BTU/h per sq ft for a mid-floor room with a 10 ft ceiling, some sun and two people — the room bands Indian AC brands publish, and the model our tonnage calculator uses.

Is a 1 ton AC enough for 100 or 120 sq ft?

Yes. A 100 sq ft room needs about 0.75 ton and a 120 sq ft room about 0.9 ton, so a true 1 ton covers both. Check that the unit is rated near 3,500 W — Daikin's ATKL35XV (3,520 W), Hitachi's RAS.V512PCDIST (3,516 W) and Lloyd's GLS12I3AGGSR (3,500 W) are; some 1 ton-class units are rated 3,100-3,350 W.

The exception is a 120 sq ft top-floor room with afternoon sun, which calculates to about 1.2 ton. There a 1.5 ton is right.

Is a 1.5 ton AC right for 150 or 180 sq ft?

Yes, on a middle floor. 150 sq ft needs about 1.1 ton and 180 sq ft about 1.35 ton. For 180 sq ft, pick a unit rated at 5,000 W or more — LG's AS-Q19MNXE (5,300 W), Panasonic's HU18CKY5XFMH (5,280 W) or Haier's HSU19K (5,460 W) — rather than one rated nearer 4,750 W.

On a sunny top floor, 180 sq ft calculates to about 1.85 ton, and a 2 ton is the correct buy.

Do you need 2 ton for 200, 250 or 300 sq ft?

200 sq ft: usually no. A middle-floor 200 sq ft room is a 1.5 ton load. It needs 2 ton only on a top floor, with strong afternoon sun, or with several people regularly in it.

250 sq ft: yes, and a true 2 ton rated close to 7,000 W — Daikin's FTKL71XV or Hitachi's Sumo RAS.Y324PCDISL. Units rated 6,100-6,300 W suit about 230-240 sq ft.

300 sq ft: about 2.25 ton, more than one 2 ton AC delivers. Two units — two 1.5 ton, or a 2 ton plus a 1 ton — cool evenly and give you a backup.

What changes the answer

  • Top floor, roof slab above: add about 20%.
  • West or south-facing with large windows: add about 15%.
  • 12 ft ceiling instead of 10 ft: add about 20%.
  • Extreme dry heat (Delhi, Rajasthan, Nagpur, UP): add about 10%.
  • Each person beyond two: add about 600 BTU/h.
  • Room open to a kitchen, or with a desktop PC or server running: add more.

Frequently asked questions

Can I use a 1.5 ton AC in a 100 sq ft room?
It will cool, but not well. An oversized AC reaches the set temperature in minutes, switches to fan and leaves moisture in the air, so the room feels cold and clammy. It also costs more. A 1 ton inverter AC, or a 1.5 ton convertible AC capped at 60%, is the better answer.
How many sq ft does a 1 ton AC cover?
About 130 sq ft for a middle-floor room with a 10 ft ceiling and ordinary sun, if the unit is rated near its full 3,517 W. On a top floor with strong afternoon sun, about 95 sq ft.
How many sq ft does a 2 ton AC cover?
About 270 sq ft on a middle floor for a unit rated close to 7,000 W, and about 230 sq ft for units rated 6,100-6,300 W. On a sunny top floor, divide by roughly 1.4.

Still not sure which air conditioner fits?

Tell us your city and situation. We will give you a straight answer — including when the honest answer is that you do not need to spend much at all.

Shortlists that follow this advice

Read next

Our current top air conditioners

See the full ranking →

Free consultation · Pan-India

Not sure what you actually need? Ask us before you spend.

Tell us your city, your water source and your budget. For homes we will recommend the right technology — including telling you when a ₹3,000 purifier is genuinely enough. For offices, societies and factories, our team will size a system against your water report and send a specification-backed quotation.

Or email betterworkindia@gmail.com — attach a water analysis report and we can quote faster.

  • Homes

    Right-sized recommendation for your TDS, not the most expensive unit

  • Offices & societies

    25 LPH to 2,000+ LPH, sized on headcount and feed water

  • Industry

    Pharma, food, textile, boiler feed — engineered to your specification

  • Service & AMC

    Installation, repair and AMC with written response times

Pan-India installation & serviceAMC support availableFree site water-quality auditCustom-engineered to your TDSHow our quotation process works →