At what fan speed can you actually sleep — and what does that cost you?

Protocol published — not yet runProtocol published 2026-06-15 · last reviewed 2026-08-08

For a given air purifier, what is the measured noise level and the measured PM2.5 decay rate at every fan speed — and how much clean air delivery is given up to reach a level someone can sleep beside?

Results

No results yet. This page publishes the protocol only.

We have written and published the method below, and we have not yet run it. There are no measurements on this page, no charts and no percentage claims, because there is nothing to report.

The protocol is published first deliberately. It means we cannot quietly amend the method once we have seen a result we did not like, and it lets anyone — including manufacturers — tell us the method is wrong before we run it. If you can see a flaw in it, tell us.

The protocol

Measure A-weighted sound pressure at 1 m at every fan speed, in the same session as the PM2.5 decay protocol, and publish decay rate and noise level as a paired figure for each speed.

Instrument

Class 2 sound level meter, A-weighted, slow response; laser particle counter

Model: To be stated on first published run

Calibration: Sound level meter checked with an acoustic calibrator before and after each session. Background room level measured and stated; any session with background above 30 dB(A) is discarded.

What is held constant

  • Microphone at 1 m from the unit, at 1 m height, off-axis from the discharge, on a stand rather than handheld.
  • Background noise measured immediately before each reading and stated with the result.
  • Same room as the decay protocol, with the same sealing, so acoustic conditions are constant.
  • Measurements taken at night to keep background level low and constant.
  • Every fan speed measured, including the sleep or auto mode, with auto mode's actual selected speed noted.

Steps

  1. 1

    Establish the background

    Measure and record the room's background sound level with everything off. If it is above 30 dB(A), the session cannot produce a usable low-speed figure and is rescheduled.

  2. 2

    Measure at every fan speed

    Allow the unit 60 seconds to stabilise at each speed, then record a 30-second average. Note the speed label as printed on the unit.

  3. 3

    Pair with decay measurement

    Run the PM2.5 decay protocol at the lowest speed, the speed we judge sleepable, and maximum, so each noise figure has a performance figure attached to it.

  4. 4

    Publish the pairing

    A table of speed, dB(A) at 1 m, background level, and 30-minute PM2.5 reduction — so a reader can find the row they could sleep next to and see what it delivers.

What this test cannot tell you

Published with the protocol rather than buried after the results. A test whose limits are not stated is a claim, not a measurement.

  • A Class 2 sound level meter is adequate for comparative measurement and is not laboratory-grade acoustic testing.
  • Perceived loudness is not the same as sound pressure level. A unit with a tonal whine can be more disturbing at 40 dB(A) than a broadband one at 44, and dB(A) does not capture that. We describe the character of the noise in words alongside the number.
  • Room acoustics affect the measurement. Figures are comparable between units tested in our room and are not directly comparable to a manufacturer's anechoic-chamber figure.
  • What counts as sleepable is a judgement. We state our judgement explicitly and publish every speed's data so a reader can apply their own.

Note

We are not an accredited testing laboratory and we do not present these as certified results. This is a published method, run consistently, with raw data and limitations disclosed — which is a different and more modest claim than certification, and we would rather make the modest one accurately.

Frequently asked questions

Why is my air purifier's CADR different at night?
Because CADR is normally quoted at maximum fan speed, and at night you are running it much slower. Clean air delivery falls roughly in proportion to airflow, so a unit rated 400 m³/h on maximum may be delivering well under half that on its sleep setting — which is the setting it spends most of its life on.
What is a quiet air purifier in dB?
Below about 30 dB(A) at 1 m is genuinely quiet in a bedroom; 35 to 40 is noticeable but tolerable for most people; above 45 few people will sleep next to it. A dB figure is only comparable if it states the measurement distance, the weighting and the background level — most marketing figures state none of the three.

Related protocols

Free consultation · Pan-India

Not sure what you actually need? Ask us before you spend.

Tell us your city, your water source and your budget. For homes we will recommend the right technology — including telling you when a ₹3,000 purifier is genuinely enough. For offices, societies and factories, our team will size a system against your water report and send a specification-backed quotation.

Or email betterworkindia@gmail.com — attach a water analysis report and we can quote faster.

  • Homes

    Right-sized recommendation for your TDS, not the most expensive unit

  • Offices & societies

    25 LPH to 2,000+ LPH, sized on headcount and feed water

  • Industry

    Pharma, food, textile, boiler feed — engineered to your specification

  • Service & AMC

    Installation, repair and AMC with written response times

Pan-India installation & serviceAMC support availableFree site water-quality auditCustom-engineered to your TDSHow our quotation process works →